<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="https://www.jain.com/assets/img/6adafce5-1.1"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Server Hardware &#8211; Jain.com</title>
	<atom:link href="https://www.jain.com/tag/server-hardware/feed" rel="self" type="application/rss+xml" />
	<link>https://www.jain.com/</link>
	<description>Data centers, connectivity, and security — news and analysis</description>
	<lastBuildDate>Sat, 26 Sep 2026 04:30:41 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.jain.com/assets/img/e2794d1c-jain-com-icon-512-150x150.png</url>
	<title>Server Hardware &#8211; Jain.com</title>
	<link>https://www.jain.com/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>GPU Liquid Cooling Cuts Fans, Not Heat: Ventiva&#8217;s 1-2 CFM Bet on the Back of the Rack</title>
		<link>https://www.jain.com/ventiva-fanless-ionic-cooler-data-center-15-percent-fan-energy</link>
		
		<dc:creator><![CDATA[Deepak Jain]]></dc:creator>
		<pubDate>Sat, 18 Jul 2026 16:00:00 +0000</pubDate>
				<category><![CDATA[Cooling Infrastructure]]></category>
		<category><![CDATA[AI infrastructure]]></category>
		<category><![CDATA[data center cooling]]></category>
		<category><![CDATA[direct-to-chip cooling]]></category>
		<category><![CDATA[energy efficiency]]></category>
		<category><![CDATA[liquid cooling]]></category>
		<category><![CDATA[Server Hardware]]></category>
		<category><![CDATA[Ventiva]]></category>
		<guid isPermaLink="false">https://www.jain.com/ventiva-fanless-ionic-cooler-data-center-15-percent-fan-energy</guid>

					<description><![CDATA[Ventiva is qualifying a fanless ionic cooler for data center servers to cool the network, boot and memory cards left hot when liquid cooling removes fans. The 15% figure is fans' share of facility energy, not a measured saving from the device itself.]]></description>
										<content:encoded><![CDATA[<div class="jain-post-grid">
<div class="jain-post-main">
<section class="jain-tldr" aria-label="Plain-English summary">
<p class="jain-tldr-kicker">TL;DR · 30-second read</p>
<h2>The Short Version</h2>
<p>Data centers are full of computers that run hot, and fans have long blown that heat away. Fans alone use about 15% of a data center&#8217;s electricity, according to one company&#8217;s chief executive.</p>
<p>Newer servers pipe liquid directly over their hottest chips, so many fans can be removed. The catch: smaller parts nearby, like network and memory cards, can then overheat and slow the whole machine down.</p>
<p>Ventiva makes a tiny, silent air mover with no moving parts that uses electrically charged air to cool those parts. It is still being tested, and laptops get it before data centers do.</p>
</section>
<p>Ventiva, a cooling technology company founded about 15 years ago as Thorn Micro Technologies, is qualifying a fanless “ionic air mover” for use inside data center servers. CEO Carl Schlachte told Facilities Dive that the device is aimed at a specific problem created by direct-to-plate liquid cooling. When operators remove bulk fans after moving processors onto liquid-cooled plates, lower-value components such as network interface cards (NICs), boot-optimized storage solution (BOSS) cards and memory modules (DIMMs) can overheat and throttle server performance.</p>
<p>According to Schlachte, fans consume about 15% of the energy flowing into data centers, and the component needs only one or two cubic feet per minute (CFM) of airflow to cool those parts. Ventiva is qualifying the device with server manufacturers for the rest of 2026. First shipments go into laptops and mini PCs next year, and data center deployments follow.</p>
<h2>Executive Summary</h2>
<p>The announcement is less about a new way to cool a data center and more about a gap in an existing one. Direct-to-plate liquid cooling runs coolant through metal plates mounted on the hottest chips, the CPUs and GPUs, and it lets operators strip out many of the bulk fans that used to push air through a server. Removing those fans saves energy. It also removes the incidental airflow that kept everything else in the chassis cool. Ventiva is selling a product for that residual heat.</p>
<p>This matters because liquid cooling adoption is being driven by dense GPU servers, and every liquid-cooled server still contains air-cooled parts. If those parts throttle, operators lose some of the performance they paid for. Ventiva&#8217;s pitch is that a solid-state air mover built into the card can recover it without bringing the fans back.</p>
<p>The 15% figure attached to the story needs careful reading. It describes fans&#8217; share of data center energy as Schlachte characterised it. It is not a measured saving from Ventiva&#8217;s device, which targets component temperature and performance rather than facility power.</p>
<h2>Liquid Cooling Moves the Heat Problem Rather Than Ending It</h2>
<p>A cold plate cools only the chip it touches. In a conventional air-cooled server, bulk fans pull a large volume of air front to back, and that stream cools the processors as well as everything downstream of them: network cards, boot drives, memory modules and power components. When direct-to-plate cooling takes over the processors, operators can reduce or remove those fans. The processors are fine. The components that were riding along in the airflow lose their cooling.</p>
<p>This is the mechanism behind the headline. Schlachte described servers that were “throttling due to overheating at the back”, meaning the chips automatically slowed down to protect themselves. He said the fix does not require much air: one or two CFM moving between DIMMs is enough for things to “start to get better almost immediately.” For comparison, a single conventional server fan is designed to move far more air than that. The operational point is that a liquid-cooled server needs very little airflow for its residual components, but it still needs some, and it needs that airflow in the right place. A device small enough to sit on the card itself could supply it.</p>
<p>The people affected are server manufacturers designing liquid-cooled platforms and operators retrofitting air-cooled halls with direct-to-plate systems. In both cases, the residual air-cooled load is a design problem. It does not disappear when the coolant loop goes in.</p>
<h2>Reading the 15% Correctly</h2>
<p>Coverage of the launch attached a 15% energy efficiency figure to the device. As Schlachte described it, 15% is the approximate share of data center energy consumed by fans. That figure is the reason operators want to remove fans, and removing them is a benefit of liquid cooling. Ventiva&#8217;s product does not produce that saving. At most, it makes the saving easier to keep by solving the thermal side effect.</p>
<p>The company&#8217;s own performance claims are softer and not yet quantified in public. Schlachte said upgraded servers would run “some double-digit percentage better” and suggested operators would get “15% more uptime.” Neither figure came with a test configuration, workload or baseline. Uptime is normally measured as the share of time a system is available, so a 15% improvement implies a starting point that few production data centers would accept. The claim may mean fewer throttling events or fewer thermal faults, but it has not been defined. These are plausible directions of benefit, but they are not substantiated results, and buyers should treat them as hypotheses until qualification data is published.</p>
<h2>An OEM Channel, Not a Facilities Purchase</h2>
<p>Ventiva&#8217;s route to data centers runs through server manufacturers. Schlachte described OEMs approaching facilities managers to propose an off-cycle upgrade: technicians would swap existing BOSS cards, NICs or DIMMs for versions with the air mover built in. He framed this as “no hit to you in terms of bottom line.” That framing leaves open who absorbs the cost of the new cards and the technician time.</p>
<p>This channel has advantages. The unit of adoption is a card, not a cooling plant, so an operator can trial it in a handful of servers without facility engineering work. It also depends on OEMs qualifying and warrantying the parts, which is why Ventiva is spending the rest of 2026 on qualification and thermal simulation. The sequencing reflects that dependency: laptops and mini PCs first next year, and data centers after that.</p>
<h2>Old Physics, New Operating Conditions</h2>
<p>The underlying principle, electrohydrodynamic flow, is well established. A charged wire creates a small plasma field that ionises nitrogen and oxygen molecules in the air. The ions drift toward a negatively charged collector and drag neutral air along with them, producing a breeze with no blades or motor. Schlachte noted that people have observed the effect for about 300 years. Removing moving parts removes a common failure point, and small size allows placement directly on a component.</p>
<p>The engineering question is whether that principle holds up for years inside a server, in a hall with its own dust, humidity and maintenance regimes. Ventiva has said it has cards running and simulations under way. It has not yet published the reliability, efficiency and service-life data that operators and OEMs use to decide whether a new component belongs in production racks.</p>
<h2>Background</h2>
<p>Data centers have traditionally been cooled with air: room-level systems chill the air, and fans inside each server pull it across the components. As processors, especially the GPUs used for AI workloads, have grown denser and hotter, operators have adopted direct-to-plate liquid cooling, which carries heat away from the hottest chips through coolant-filled plates. That shift lets operators reduce the number of bulk fans, which Ventiva&#8217;s CEO says account for roughly 15% of data center energy use.</p>
<p>Ventiva, originally Thorn Micro Technologies, has spent about 15 years developing solid-state air movers based on electrohydrodynamic flow, the airflow produced when charged ions travel between a wire and a collector. The company is positioning the technology first in compact consumer devices and then in servers. There, it targets components that are not on the liquid cooling loop but still need a small, steady supply of air.</p>
<section class="jain-sources" aria-label="Sources">
<h2>Sources</h2>
<p>Source: <a href="https://news.google.com/rss/articles/CBMitgFBVV95cUxQTkQ2Q0xpbWtaMXBxRkludEhBQ0lWclRnOHZ5cDJuZkFuOVRySVMwVlBBU05aOW9uSzNvQTU2SUpWYnQ2b3I2U2dweGVuelRicGZESWJGSzlwaWk4NjNGT3lHcFpwRGJBSGc1OFBpa0FleW90MFJvRFBxR2RJVUlOVUJONTZLLU1mR3ExWHlrZUVIak84eGlyM0ZSalR3Y1pEZG5XQVNYMV9SM1BXYWpVaUhLT2NNUQ?oc=5">Ventiva touts fanless cooler for 15% data center energy efficiency gains</a> — Facilities Dive&#8217;s interview with Ventiva CEO Carl Schlachte on the company&#8217;s ionic air mover for liquid-cooled servers.</p>
</section>
</div>
<aside class="jain-rail">
<section class="jain-gaps" aria-label="What the release does not say">
<p class="jain-gaps-kicker">⚠ What They Aren’t Saying</p>
<h2>What the Release Doesn&#8217;t Say</h2>
<ul>
<li><strong>Performance evidence:</strong> Ventiva has not published test data showing how much throttling its air mover eliminates, on which server platforms, under which workloads, or how “15% more uptime” and “double-digit percentage better” were measured.</li>
<li><strong>Power draw and byproducts:</strong> The company has not disclosed how much electricity each air mover consumes. It also has not said whether the ionisation process generates ozone, a known byproduct of corona discharge, or how the wire and collector handle dust accumulation over a server&#8217;s service life.</li>
<li><strong>OEM commitments and economics:</strong> Ventiva has not named the server manufacturers qualifying its cards, given a date for data center availability beyond “after” next year&#8217;s laptop shipments, or said who pays for off-cycle card replacements and at what price.</li>
</ul>
</section>
<section class="jain-faq">
<h2>Frequently Asked Questions</h2>
<h3>What did Ventiva announce?</h3>
<p>Ventiva is qualifying a fanless ionic air mover designed to be built into server components such as network cards, boot storage cards and memory modules, to cool parts that can overheat after liquid cooling lets operators remove bulk fans.</p>
<h3>Does Ventiva&#x27;s device save 15% of data center energy?</h3>
<p>Not directly. CEO Carl Schlachte said fans consume about 15% of the energy flowing into data centers. Removing fans is what saves energy, and liquid cooling makes that possible. Ventiva&#8217;s device targets the overheating that fan removal can cause.</p>
<h3>How does an ionic air mover work?</h3>
<p>An electrified wire creates a small plasma field that ionises nitrogen and oxygen in the air. The charged ions drift toward a negatively charged collector and pull surrounding air with them, producing airflow with no blades or motor. The effect is called electrohydrodynamic flow.</p>
<h3>What is direct-to-plate liquid cooling?</h3>
<p>It is a method that pumps coolant through metal plates mounted directly on hot chips such as CPUs and GPUs. It removes heat far more effectively than air, which is why it is spreading with dense AI servers, but it only cools the chips it touches.</p>
<h3>Why would removing fans cause other parts to overheat?</h3>
<p>Bulk server fans cool everything in their airflow path, not just processors. When liquid cooling takes over the processors and fans are removed, components like network cards and memory lose that incidental airflow and can heat up enough to throttle.</p>
<h3>What does throttling mean for a server?</h3>
<p>Throttling is when a component automatically slows itself down to avoid heat damage. It protects the hardware but reduces performance, so a server that throttles is delivering less computing work than the operator paid for.</p>
<h3>How much airflow does Ventiva say is needed?</h3>
<p>Schlachte said one or two cubic feet per minute of air moving between memory modules is enough for components to start running cooler almost immediately. That is a very small volume compared with what conventional server fans move.</p>
<h3>What are NIC and BOSS cards?</h3>
<p>A NIC, or network interface card, connects a server to the network. A BOSS card, or boot-optimized storage solution, holds the drives a server boots from. Both are essential but are not usually on the liquid cooling loop.</p>
<h3>How would operators install Ventiva&#x27;s technology?</h3>
<p>Server technicians would replace existing BOSS cards, NICs or memory modules with versions that have the air mover built in. Ventiva expects server manufacturers to offer this to facilities managers as an off-cycle upgrade.</p>
<h3>When will Ventiva&#x27;s air mover be available for data centers?</h3>
<p>Ventiva said it is qualifying the device with server manufacturers for the rest of 2026. First shipments go into laptops and mini PCs next year, with data center deployments to follow. No specific data center date was given.</p>
<h3>Has Ventiva proved its uptime and performance claims?</h3>
<p>Not publicly. Schlachte cited 15% more uptime and double-digit performance gains, but no test methodology, baseline or workload has been published. The company says cards are running and thermal simulations are under way.</p>
<h3>Who is Ventiva?</h3>
<p>Ventiva is a cooling technology company that launched about 15 years ago as Thorn Micro Technologies, built around using ionic airflow to cool electronics. Carl Schlachte is its CEO.</p>
<h3>Does this replace liquid cooling?</h3>
<p>No. Ventiva positions its air mover as a complement to direct-to-plate liquid cooling, handling the small residual heat loads on components the cold plates do not reach, so operators can keep fan counts low.</p>
<h3>What should data center operators ask before adopting it?</h3>
<p>Operators should ask for measured throttling and temperature data on their server platforms, the device&#8217;s power draw, any ozone output, maintenance and dust behaviour, OEM warranty coverage, and who pays for the card swaps.</p>
</section>
</aside>
</div>
<p><script type="application/ld+json">{"@context": "https://schema.org", "@graph": [{"@type": "NewsArticle", "headline": "GPU Liquid Cooling Cuts Fans, Not Heat: Ventiva's 1-2 CFM Bet on the Back of the Rack", "description": "Ventiva is qualifying a fanless ionic cooler for data center servers to cool the network, boot and memory cards left hot when liquid cooling removes fans. The 15% figure is fans' share of facility energy, not a measured saving from the device itself.", "image": ["https://www.jain.com/assets/img/39c56229-ventiva-fanless-ionic-air-mover-data-center-server-cooling.webp"], "author": {"@type": "Organization", "name": "jain.com Editorial"}, "datePublished": "2026-09-26T04:30:39.513859+00:00"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "What did Ventiva announce?", "acceptedAnswer": {"@type": "Answer", "text": "Ventiva is qualifying a fanless ionic air mover designed to be built into server components such as network cards, boot storage cards and memory modules, to cool parts that can overheat after liquid cooling lets operators remove bulk fans."}}, {"@type": "Question", "name": "Does Ventiva's device save 15% of data center energy?", "acceptedAnswer": {"@type": "Answer", "text": "Not directly. CEO Carl Schlachte said fans consume about 15% of the energy flowing into data centers. Removing fans is what saves energy, and liquid cooling makes that possible. Ventiva's device targets the overheating that fan removal can cause."}}, {"@type": "Question", "name": "How does an ionic air mover work?", "acceptedAnswer": {"@type": "Answer", "text": "An electrified wire creates a small plasma field that ionises nitrogen and oxygen in the air. The charged ions drift toward a negatively charged collector and pull surrounding air with them, producing airflow with no blades or motor. The effect is called electrohydrodynamic flow."}}, {"@type": "Question", "name": "What is direct-to-plate liquid cooling?", "acceptedAnswer": {"@type": "Answer", "text": "It is a method that pumps coolant through metal plates mounted directly on hot chips such as CPUs and GPUs. It removes heat far more effectively than air, which is why it is spreading with dense AI servers, but it only cools the chips it touches."}}, {"@type": "Question", "name": "Why would removing fans cause other parts to overheat?", "acceptedAnswer": {"@type": "Answer", "text": "Bulk server fans cool everything in their airflow path, not just processors. When liquid cooling takes over the processors and fans are removed, components like network cards and memory lose that incidental airflow and can heat up enough to throttle."}}, {"@type": "Question", "name": "What does throttling mean for a server?", "acceptedAnswer": {"@type": "Answer", "text": "Throttling is when a component automatically slows itself down to avoid heat damage. It protects the hardware but reduces performance, so a server that throttles is delivering less computing work than the operator paid for."}}, {"@type": "Question", "name": "How much airflow does Ventiva say is needed?", "acceptedAnswer": {"@type": "Answer", "text": "Schlachte said one or two cubic feet per minute of air moving between memory modules is enough for components to start running cooler almost immediately. That is a very small volume compared with what conventional server fans move."}}, {"@type": "Question", "name": "What are NIC and BOSS cards?", "acceptedAnswer": {"@type": "Answer", "text": "A NIC, or network interface card, connects a server to the network. A BOSS card, or boot-optimized storage solution, holds the drives a server boots from. Both are essential but are not usually on the liquid cooling loop."}}, {"@type": "Question", "name": "How would operators install Ventiva's technology?", "acceptedAnswer": {"@type": "Answer", "text": "Server technicians would replace existing BOSS cards, NICs or memory modules with versions that have the air mover built in. Ventiva expects server manufacturers to offer this to facilities managers as an off-cycle upgrade."}}, {"@type": "Question", "name": "When will Ventiva's air mover be available for data centers?", "acceptedAnswer": {"@type": "Answer", "text": "Ventiva said it is qualifying the device with server manufacturers for the rest of 2026. First shipments go into laptops and mini PCs next year, with data center deployments to follow. No specific data center date was given."}}, {"@type": "Question", "name": "Has Ventiva proved its uptime and performance claims?", "acceptedAnswer": {"@type": "Answer", "text": "Not publicly. Schlachte cited 15% more uptime and double-digit performance gains, but no test methodology, baseline or workload has been published. The company says cards are running and thermal simulations are under way."}}, {"@type": "Question", "name": "Who is Ventiva?", "acceptedAnswer": {"@type": "Answer", "text": "Ventiva is a cooling technology company that launched about 15 years ago as Thorn Micro Technologies, built around using ionic airflow to cool electronics. Carl Schlachte is its CEO."}}, {"@type": "Question", "name": "Does this replace liquid cooling?", "acceptedAnswer": {"@type": "Answer", "text": "No. Ventiva positions its air mover as a complement to direct-to-plate liquid cooling, handling the small residual heat loads on components the cold plates do not reach, so operators can keep fan counts low."}}, {"@type": "Question", "name": "What should data center operators ask before adopting it?", "acceptedAnswer": {"@type": "Answer", "text": "Operators should ask for measured throttling and temperature data on their server platforms, the device's power draw, any ozone output, maintenance and dust behaviour, OEM warranty coverage, and who pays for the card swaps."}}]}]}</script></p>