	<title>CRAH &#8211; Jain.com</title>
	<atom:link href="/tag/crah/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description>Data centers, connectivity, and security — news and analysis</description>
	<lastBuildDate>Mon, 31 Aug 2026 11:27:27 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>/wp-content/uploads/2026/08/jain-com-icon-512-150x150.png</url>
	<title>CRAH &#8211; Jain.com</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>LONGWELL&#8217;s FanWall Claim: 38% Less CRAH Fan Energy</title>
		<link>/longwell-fanwall-38-percent-crah-fan-energy-savings/</link>
		
		<dc:creator><![CDATA[Deepak Jain]]></dc:creator>
		<pubDate>Mon, 31 Aug 2026 11:27:27 +0000</pubDate>
				<category><![CDATA[Cooling Infrastructure]]></category>
		<category><![CDATA[AI data centers]]></category>
		<category><![CDATA[CRAH]]></category>
		<category><![CDATA[data center cooling]]></category>
		<category><![CDATA[EC Fans]]></category>
		<category><![CDATA[energy efficiency]]></category>
		<category><![CDATA[PUE]]></category>
		<category><![CDATA[Supply Chain]]></category>
		<guid isPermaLink="false">/longwell-fanwall-38-percent-crah-fan-energy-savings/</guid>

					<description><![CDATA[LONGWELL says its LWBE3G FanWall arrays cut CRAH fan energy by 38% and moved from spec validation to mass production in 90 days. Here is what that claim establishes, what the release leaves open on operating points and the unnamed OEM partner, and where air-side efficiency fits in a liquid-cooled future.]]></description>
										<content:encoded><![CDATA[<div class="jain-post-grid">
<div class="jain-post-main">
<p>Ningbo Longwell Electric Technology Co., Ltd. (LONGWELL), a Chinese fan and motor manufacturer founded in 1990, announced on 31 August 2026 an AI-era data center cooling line built around its LWBE3G EC plug-fan platform. Deployed as a FanWall array — a bank of smaller fans replacing one large fan — the company reports a 38% reduction in CRAH fan energy consumption, a 6.5 dB(A) noise reduction, and no field failures on the project cited.</p>
<p>The work was done with what LONGWELL describes as one of the world&#8217;s top three precision-cooling OEMs, which it does not name. LONGWELL says it delivered 12 engineering samples in 35 days, passed DV/PV testing 100% on the first attempt, and went from specification validation to mass production in 90 days. The first customer order was 1,500 units; 2025 deliveries exceeded 80,000 units under a 2025–2027 framework agreement with a stated annual minimum of 60,000 units.</p>
<h2>Executive Summary</h2>
<p>The headline number is a 38% cut in the electricity drawn by the fans inside CRAH units — the computer-room air handlers that push cold air through a data hall. LONGWELL also reports that the CRAH system&#8217;s contribution to the facility energy-efficiency metric improved from a 1.42 baseline to 1.28 on the project in question. Fan power is one of the largest non-IT loads in an air-cooled hall, so a double-digit percentage cut there is economically meaningful even though it changes nothing about the servers themselves.</p>
<p>The second, arguably more consequential claim is about speed. LONGWELL states that the incumbent European supplier on the same program had scheduled 14 months of development plus six months of production ramp, while LONGWELL completed spec-validation-to-mass-production in 90 days. If that comparison holds up, it says something about how quickly the precision-cooling supply chain can be re-sourced when AI buildouts compress every schedule — and about competitive pressure on established European fan vendors.</p>
<p>The context is thermal density. LONGWELL cites rack loads moving from 15–20 kW to 60–100 kW in two years, with next-generation platforms exceeding 100 kW. That trajectory is usually cited as the argument for liquid cooling. This announcement makes the opposite-facing point: the air side of the plant still exists, still consumes power, and still has efficiency headroom that operators can capture without re-plumbing a building.</p>
<h2>Fan Power Is the Quiet Line Item in Data Center Energy</h2>
<p>In an air-cooled data hall, electricity splits between the IT equipment and everything that supports it: chillers, pumps, power conversion losses, and air movement. The air-movement share is easy to overlook because no single fan looks expensive, but CRAH fans run continuously, at every hour of every day, for the life of the facility. That duty cycle is what turns a percentage into money. A 38% reduction on a load that never switches off compounds differently from a 38% reduction on something that runs during business hours.</p>
<p>The physics behind FanWall designs is not exotic and is worth stating plainly for non-specialists: fan power rises steeply with speed, so several smaller fans each running slower can move the same air volume for less power than one large fan running hard. EC — electronically commutated — motors, which use electronic control rather than mechanical brushes, make that easier by allowing precise, continuous speed modulation instead of on-off cycling. The array also degrades gracefully; LONGWELL cites automatic N+1 failover, meaning the array carries a spare fan&#8217;s worth of capacity so a single failure does not force a shutdown.</p>
<p>None of that is unique to LONGWELL. FanWall architectures and EC motors are established practice across precision cooling, which is precisely why the interesting question in this release is not whether the approach works but what specifically LONGWELL&#8217;s platform was replacing, and at what operating point. The release&#8217;s own footnote says the comparative energy data refer to the equipment displaced on that project.</p>
<h2>Ninety Days Versus Twenty Months: The Real Competitive Story</h2>
<p>Component qualification is normally the slowest, least glamorous part of building cooling equipment. An OEM cannot simply swap a fan; it must re-run design verification and production validation testing, requalify acoustics and vibration, and re-certify the assembled unit. That is why the incumbent&#8217;s quoted 14-month development plus six-month ramp is not obviously unreasonable — it is roughly the industry&#8217;s normal cadence. LONGWELL&#8217;s claim is that it collapsed the same sequence to 90 days, with 12 engineering samples inside 35 days and a first-pass DV/PV result.</p>
<p>For buyers, first-pass DV/PV is the detail worth noticing. Test cycles fail routinely, and each failure costs weeks. A supplier that passes on the first attempt is signalling that its engineering samples already matched the specification, which is a manufacturing-maturity claim as much as a design one. For the precision-cooling OEMs racing to fill AI-driven order books, a supplier who can compress twenty months into three is solving a scheduling problem, not just a component-cost problem.</p>
<p>The competitive read is straightforward and should be stated without overreach: European fan suppliers have long held strong positions in HVAC and data center air movement on the strength of engineering depth and long qualification relationships. Speed of response is now being priced alongside that. The release does not claim the incumbent&#8217;s product was technically inferior — only that its timeline was longer on this program — and it explicitly disclaims any affiliation or endorsement.</p>
<h2>What the 38% Establishes, and What It Does Not</h2>
<p>LONGWELL is unusually candid in its own disclaimer: the performance data correspond to a specific project and a specific operating point, and final selection must be confirmed against operating point, voltage and control scheme, mounting arrangement, and project validation. That caveat is doing real work. Fan performance is highly sensitive to the pressure the fan works against, and a figure measured in one CRAH cabinet at one airflow does not transfer automatically to another.</p>
<p>The 1.42-to-1.28 figure deserves particular care. Those numbers are in the numerical range of PUE — power usage effectiveness, the ratio of total facility power to IT power, where 1.0 is theoretically perfect — but the release describes this as the CRAH system&#8217;s contribution to the efficiency metric on this project, not a whole-facility PUE for a named site. Read as a subsystem-level improvement it is a coherent result; read as a facility PUE it would be a much larger claim than the release supports. The distinction matters for anyone modelling savings.</p>
<p>The commercial figures are the most independently checkable part of the announcement, in the sense that they describe behaviour rather than test conditions. A first order of 1,500 units expanding to more than 80,000 units delivered in 2025, under a 2025–2027 framework with a 60,000-unit annual minimum, is a customer voting with volume. It is not third-party verification of 38%, but repeat purchasing at that scale is a stronger signal than a datasheet.</p>
<h2>Air Cooling Does Not Disappear Because Liquid Arrives</h2>
<p>The prevailing narrative says racks above roughly 60–100 kW must go to liquid cooling, and for the densest AI training clusters that is broadly where the industry is heading. But the transition is neither instant nor total. Direct-to-chip liquid cooling typically removes most, not all, of a rack&#8217;s heat; the remainder still leaves via air. Storage, networking, and general-purpose compute remain air-cooled. Retrofit halls with existing CRAH fleets will keep running for years on depreciation schedules that do not care about GPU roadmaps. Condensers and cooling towers — LONGWELL&#8217;s LWAE3G axial fan line targets these — are needed in liquid-cooled plants too.</p>
<p>That is the strongest version of this announcement&#8217;s editorial premise: air-side efficiency has remaining headroom precisely because it is being treated as legacy. Capital and attention are flowing toward liquid, which leaves ordinary optimisation of the air path comparatively under-exploited. Operators who cannot re-plumb a building this year can still change fans.</p>
<p>The counter-risk for a supplier in this position is that it is selling into a segment whose long-run share of new-build capacity may shrink even as its absolute installed base stays large. LONGWELL&#8217;s stated data center fan capacity of more than 120,000 units annually against a 60,000-unit contractual minimum suggests it has built for growth beyond this one customer; whether that growth comes from new AI halls, retrofits of existing ones, or the condenser and cooling-tower side of liquid-cooled plants is not something the release addresses.</p>
<h2>Background</h2>
<p>Precision cooling — the equipment class covering CRAC and CRAH units that hold data halls at controlled temperature and humidity — has historically been dominated by a small group of global OEMs, which in turn buy fans and motors from a specialist supply chain long anchored by European manufacturers. Fans are qualified rather than simply purchased: each one must pass verification testing inside the OEM&#8217;s cabinet, so incumbency has been durable and switching slow.</p>
<p>The AI compute buildout has strained that arrangement. As per-rack heat loads climbed from the 15–20 kW typical of general-purpose servers toward 60–100 kW and beyond for accelerated computing, OEMs have needed higher-performance air movement on schedules far shorter than the industry&#8217;s traditional multi-year qualification cadence. LONGWELL, a Ningbo-area manufacturer founded in 1990 and long active in HVAC-R and industrial fans, is one of several Asian suppliers positioning against that compressed timeline — an announcement that is as much about procurement velocity as about thermodynamics.</p>
<p>Source: <a href="https://www.prnewswire.com/news-releases/la-technologie-fanwall-de-longwell-ec-permet-de-reduire-de-38--la-consommation-energetique-des-ventilateurs-crah-des-centres-de-donnees-ia-de-nouvelle-generation-302864806.html">La technologie FanWall de LONGWELL EC permet de réduire de 38 % la consommation énergétique des ventilateurs CRAH des centres de données IA de nouvelle génération</a> — PR Newswire release, dated 31 August 2026 from Ningbo, China, detailing LONGWELL&#8217;s LWBE3G EC plug-fan platform, its reported CRAH fan energy and acoustic results, and the volumes shipped under a 2025–2027 framework agreement.</p>
</div>
<aside class="jain-rail">
<section class="jain-gaps" aria-label="What the release does not say">
<p class="jain-gaps-kicker"><img src="https://www.jain.com/assets/img/dbaaff79-26a0.png" alt="⚠" class="wp-smiley" style="height: 1em; max-height: 1em;" /> What They Aren’t Saying</p>
<h2>What the Release Doesn&#8217;t Say</h2>
<p>The release leaves several material questions open. The OEM partner is described only as one of the world&#8217;s top three precision-cooling manufacturers and is not named, so the claim cannot be corroborated with the buyer. Nor is the displaced European supplier identified, which makes the 90-days-versus-20-months comparison impossible to check from either side. No end customer, site, or geography is disclosed for the deployment that produced the 38% and 6.5 dB(A) results.</p>
<p>Technically, the release gives percentages but no absolutes: no baseline fan power in kilowatts, no airflow or static-pressure operating point, no indication whether the displaced fans were older AC units or a prior EC generation — a distinction that materially changes how impressive 38% is. The 1.42-to-1.28 metric is not defined precisely enough to tell whether it is a subsystem calculation or a measured facility PUE, and no third-party or independent test verification is cited. Nothing is said about price, capital cost, or payback period, so the economic case cannot be evaluated.</p>
<ul>
<li><strong>Commercial:</strong> Are the 80,000-plus units delivered in 2025 all data center CRAH fans, or does the figure include other HVAC-R applications? No 2026 run-rate is given despite the August 2026 release date.</li>
<li><strong>Capacity and concentration:</strong> With stated capacity above 120,000 units per year and a 60,000-unit annual minimum from one framework agreement, how much of the business depends on this single customer?</li>
<li><strong>Support and market access:</strong> What warranty, spare-parts, and field-service coverage exists in Europe and North America, and what exposure do tariffs or procurement-policy shifts create for a China-manufactured component in Western data centers?</li>
<li><strong>Predictive maintenance:</strong> The optional bearing vibration sensors are said to give 30–90 days of end-of-life warning, but no accuracy, false-positive rate, or validation basis is provided.</li>
</ul>
</section>
<section class="jain-faq">
<h2>Frequently Asked Questions</h2>
<h3>What did LONGWELL actually announce?</h3>
<p>On 31 August 2026, LONGWELL released an AI-era data center cooling line built on its LWBE3G EC plug-fan platform. Deployed as FanWall arrays, the company reports a 38% cut in CRAH fan energy use, 6.5 dB(A) lower noise, and no field failures on the project cited.</p>
<h3>What is a CRAH unit?</h3>
<p>A CRAH — computer room air handler — is the cabinet that pushes cooled air through a data hall. It uses chilled water from a central plant and a fan section to move air across the servers. Its fans run continuously, making them a persistent electrical load.</p>
<h3>What is a FanWall?</h3>
<p>A FanWall replaces one large fan with an array of smaller fans mounted together in a grid. Because fan power rises steeply with speed, several fans running slower can move the same air for less energy, and the array keeps working if one unit fails.</p>
<h3>What is an EC fan and why does it matter here?</h3>
<p>EC stands for electronically commutated: the motor is controlled electronically rather than with mechanical brushes. That allows precise, continuous speed adjustment instead of switching on and off, which is where much of the energy saving in variable-load cooling comes from.</p>
<h3>How much energy does LONGWELL say the FanWall saves?</h3>
<p>The release states a 38% reduction in CRAH fan energy consumption on the project cited. LONGWELL notes this figure corresponds to a specific project and operating point and should be confirmed against each application&#8217;s own conditions.</p>
<h3>What does the 1.42 to 1.28 figure mean?</h3>
<p>The release describes the CRAH system&#8217;s contribution to the energy-efficiency metric improving from a 1.42 baseline to 1.28. Those values sit in PUE&#8217;s numerical range, but the release presents this as a subsystem result on one project, not a verified whole-facility PUE.</p>
<h3>Who is the OEM partner behind the deployment?</h3>
<p>LONGWELL identifies the partner only as one of the world&#8217;s top three precision-cooling equipment manufacturers and does not name it. The end customer and site are also undisclosed, so the deployment cannot be independently corroborated from the release.</p>
<h3>How does the 90-day timeline compare with the incumbent supplier?</h3>
<p>LONGWELL says the incumbent European supplier had planned 14 months of development plus six months of production ramp, while LONGWELL took 90 days from specification validation to mass production. That incumbent is not named, and the release disclaims any affiliation or endorsement.</p>
<h3>What is DV/PV testing?</h3>
<p>DV/PV means design verification and production validation — the two test stages that confirm a component meets its specification and can be built repeatably at volume. LONGWELL reports passing both 100% on the first attempt, which avoids the retest cycles that usually stretch schedules.</p>
<h3>What volumes are involved in the agreement?</h3>
<p>The first customer order was 1,500 units. LONGWELL says 2025 deliveries exceeded 80,000 units under a 2025–2027 framework agreement with a stated annual minimum of 60,000 units. The release does not give a 2026 run-rate.</p>
<h3>Who is LONGWELL?</h3>
<p>Ningbo Longwell Electric Technology Co., Ltd. was founded in 1990 in Yuyao, near Ningbo, China. It designs and manufactures EC and AC fans and motors for HVAC-R and industrial use, exports to more than 30 countries, and states annual data center fan capacity above 120,000 units.</p>
<h3>Why is rack thermal density driving this?</h3>
<p>LONGWELL cites per-rack heat loads rising from 15–20 kW to 60–100 kW within two years, with next-generation platforms exceeding 100 kW. More heat per rack means more air must be moved, so fan efficiency becomes a larger share of the facility&#8217;s energy picture.</p>
<h3>Does liquid cooling make air-side efficiency irrelevant?</h3>
<p>No. Direct-to-chip liquid cooling typically removes most but not all rack heat, storage and networking gear stays air-cooled, existing halls run for years on their installed CRAH fleets, and liquid-cooled plants still need condenser and cooling-tower fans.</p>
<h3>What monitoring and control features does the platform include?</h3>
<p>LONGWELL cites Modbus control for integration with building management systems, automatic N+1 failover so the array keeps running after a single fan failure, and optional bearing vibration sensors said to give 30–90 days of warning before end of life.</p>
<h3>What should a buyer verify before selecting these fans?</h3>
<p>LONGWELL&#8217;s own disclaimer is the checklist: confirm the operating point, voltage and control scheme, mounting arrangement, and project-specific validation. Buyers should also request baseline power in kilowatts, the fan type being displaced, pricing, and regional service coverage.</p>
</section>
</aside>
</div>
<p><script type="application/ld+json">{"@context": "https://schema.org", "@graph": [{"@type": "NewsArticle", "headline": "LONGWELL's FanWall Claim: 38% Less CRAH Fan Energy", "description": "LONGWELL says its LWBE3G FanWall arrays cut CRAH fan energy by 38% and moved from spec validation to mass production in 90 days. Here is what that claim establishes, what the release leaves open on operating points and the unnamed OEM partner, and where air-side efficiency fits in a liquid-cooled future.", "image": ["/wp-content/uploads/2026/08/longwell-fanwall-crah-fan-energy-savings.png"], "author": {"@type": "Organization", "name": "jain.com Editorial"}, "datePublished": "2026-08-31T11:27:23.747349+00:00"}, {"@type": "FAQPage", "mainEntity": [{"@type": "Question", "name": "What did LONGWELL actually announce?", "acceptedAnswer": {"@type": "Answer", "text": "On 31 August 2026, LONGWELL released an AI-era data center cooling line built on its LWBE3G EC plug-fan platform. Deployed as FanWall arrays, the company reports a 38% cut in CRAH fan energy use, 6.5 dB(A) lower noise, and no field failures on the project cited."}}, {"@type": "Question", "name": "What is a CRAH unit?", "acceptedAnswer": {"@type": "Answer", "text": "A CRAH \u2014 computer room air handler \u2014 is the cabinet that pushes cooled air through a data hall. It uses chilled water from a central plant and a fan section to move air across the servers. Its fans run continuously, making them a persistent electrical load."}}, {"@type": "Question", "name": "What is a FanWall?", "acceptedAnswer": {"@type": "Answer", "text": "A FanWall replaces one large fan with an array of smaller fans mounted together in a grid. Because fan power rises steeply with speed, several fans running slower can move the same air for less energy, and the array keeps working if one unit fails."}}, {"@type": "Question", "name": "What is an EC fan and why does it matter here?", "acceptedAnswer": {"@type": "Answer", "text": "EC stands for electronically commutated: the motor is controlled electronically rather than with mechanical brushes. That allows precise, continuous speed adjustment instead of switching on and off, which is where much of the energy saving in variable-load cooling comes from."}}, {"@type": "Question", "name": "How much energy does LONGWELL say the FanWall saves?", "acceptedAnswer": {"@type": "Answer", "text": "The release states a 38% reduction in CRAH fan energy consumption on the project cited. LONGWELL notes this figure corresponds to a specific project and operating point and should be confirmed against each application's own conditions."}}, {"@type": "Question", "name": "What does the 1.42 to 1.28 figure mean?", "acceptedAnswer": {"@type": "Answer", "text": "The release describes the CRAH system's contribution to the energy-efficiency metric improving from a 1.42 baseline to 1.28. Those values sit in PUE's numerical range, but the release presents this as a subsystem result on one project, not a verified whole-facility PUE."}}, {"@type": "Question", "name": "Who is the OEM partner behind the deployment?", "acceptedAnswer": {"@type": "Answer", "text": "LONGWELL identifies the partner only as one of the world's top three precision-cooling equipment manufacturers and does not name it. The end customer and site are also undisclosed, so the deployment cannot be independently corroborated from the release."}}, {"@type": "Question", "name": "How does the 90-day timeline compare with the incumbent supplier?", "acceptedAnswer": {"@type": "Answer", "text": "LONGWELL says the incumbent European supplier had planned 14 months of development plus six months of production ramp, while LONGWELL took 90 days from specification validation to mass production. That incumbent is not named, and the release disclaims any affiliation or endorsement."}}, {"@type": "Question", "name": "What is DV/PV testing?", "acceptedAnswer": {"@type": "Answer", "text": "DV/PV means design verification and production validation \u2014 the two test stages that confirm a component meets its specification and can be built repeatably at volume. LONGWELL reports passing both 100% on the first attempt, which avoids the retest cycles that usually stretch schedules."}}, {"@type": "Question", "name": "What volumes are involved in the agreement?", "acceptedAnswer": {"@type": "Answer", "text": "The first customer order was 1,500 units. LONGWELL says 2025 deliveries exceeded 80,000 units under a 2025\u20132027 framework agreement with a stated annual minimum of 60,000 units. The release does not give a 2026 run-rate."}}, {"@type": "Question", "name": "Who is LONGWELL?", "acceptedAnswer": {"@type": "Answer", "text": "Ningbo Longwell Electric Technology Co., Ltd. was founded in 1990 in Yuyao, near Ningbo, China. It designs and manufactures EC and AC fans and motors for HVAC-R and industrial use, exports to more than 30 countries, and states annual data center fan capacity above 120,000 units."}}, {"@type": "Question", "name": "Why is rack thermal density driving this?", "acceptedAnswer": {"@type": "Answer", "text": "LONGWELL cites per-rack heat loads rising from 15\u201320 kW to 60\u2013100 kW within two years, with next-generation platforms exceeding 100 kW. More heat per rack means more air must be moved, so fan efficiency becomes a larger share of the facility's energy picture."}}, {"@type": "Question", "name": "Does liquid cooling make air-side efficiency irrelevant?", "acceptedAnswer": {"@type": "Answer", "text": "No. Direct-to-chip liquid cooling typically removes most but not all rack heat, storage and networking gear stays air-cooled, existing halls run for years on their installed CRAH fleets, and liquid-cooled plants still need condenser and cooling-tower fans."}}, {"@type": "Question", "name": "What monitoring and control features does the platform include?", "acceptedAnswer": {"@type": "Answer", "text": "LONGWELL cites Modbus control for integration with building management systems, automatic N+1 failover so the array keeps running after a single fan failure, and optional bearing vibration sensors said to give 30\u201390 days of warning before end of life."}}, {"@type": "Question", "name": "What should a buyer verify before selecting these fans?", "acceptedAnswer": {"@type": "Answer", "text": "LONGWELL's own disclaimer is the checklist: confirm the operating point, voltage and control scheme, mounting arrangement, and project-specific validation. Buyers should also request baseline power in kilowatts, the fan type being displaced, pricing, and regional service coverage."}}]}]}</script></p>